977 resultados para Specific gravity


Relevância:

100.00% 100.00%

Publicador:

Resumo:

One of the major problems faced by coal based thermal power stations is handling and disposal of ash. Among the various uses of fly ash, the major quantity of ash produced is used in geotechnical engineering applications such as construction of embankments, as a backfill material, etc. The generally low specific gravity of fly ash resulting in low unit weight as compared to soils is an attractive property for its use in geotechnical applications. In general, specific gravity of coal ash lies around 2.0 but can vary to a large extent (1.6 to 3.1). The variation of specific gravity of coal ash is due to the combination of various factors like gradation, particle shape, and chemical composition. Since specific gravity is an important physical property, it has been studied in depth for three Indian coal ashes and reported in this paper.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Influence of moisture and specific gravity on the strength of mango wood is discussed. The co-efficient of correlation between specific gravity and breaking strength was found to be non-significant. The relation of strength and moisture was found to be highly significant. The mean strength values indicated a reduction in strength when the moisture increased from 8.5 to 18.8%. However no appreciable difference in strength values could be observed when moisture increased above 37%. The strength-moisture relationship is a straight line, passing approximately through the fibre saturation point. By using the exponential formula, the breaking strength corresponding to any moisture level between zero and fibre saturation can be determined.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we propose a new system that allows reliable acetabular cup placement when the THA is operated in lateral approach. Conceptually it combines the accuracy of computer-generated patient-specific morphology information with an easy-to-use mechanical guide, which effectively uses natural gravity as the angular reference. The former is achieved by using a statistical shape model-based 2D-3D reconstruction technique that can generate a scaled, patient-specific 3D shape model of the pelvis from a single conventional anteroposterior (AP) pelvic X-ray radiograph. The reconstructed 3D shape model facilitates a reliable and accurate co-registration of the mechanical guide with the patient’s anatomy in the operating theater. We validated the accuracy of our system by conducting experiments on placing seven cups to four pelvises with different morphologies. Taking the measurements from an image-free navigation system as the ground truth, our system showed an average accuracy of 2.1 ±0.7 o for inclination and an average accuracy of 1.2 ±1.4 o for anteversion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The constitution of the ternary mattes Cu2S PbS Sb2S3 has never been completely investigated nor has there been any attempt to draw the complete ternary diagram. The following work is intended to [be] a contribution towards completion of this diagram by determining the specific gravity of different mattes and by pointing out some which show peculiarities of structure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The constitution of the ternary mattes CU2S-FeS-PbS has never been completely investigated. Fulton and Goodner 1) have investigated the binary mattes CU2S-FeS, CU2S-PbS, PbSFeS and have shown that the three binaries show eutectics. There has been no attempt however to draw the complete ternary diagram. The following work is intended to be a contribution toward the completion of this diagram by first of all pointing out those mattes which separate on melting into two layers, and second by determining the specific gravities of mattes of different compositions.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The specific gravity of urine (SG) indicates the number and weight of solute particles in urine; its measurement is helpful in interpreting proteinuria detected by dipstick tests and in monitoring adequate hydration in patients with nephrolithiasis. Four methods for measuring SG or osmolality of urine are currently available (depression of the freezing-point, urometry, refractometry, cation exchange on a reagent strip). Using a recently developed reagent strip, we have measured SG in morning urines of 340 non-selected outpatients and compared the results with SG measurements by refractometry of the same urines. In 86.2% of all urines, a good positive correlation between SG measured by reagent strip and refractometry was noted (r = 0.913, p = 0.0001). In 13.8% of the urines, however, the SG measured by reagent strip deviated by more than +/- 5 from the value obtained by refractometry; in 90% of these urines, glucosuria (reagent strip values too low or too high), proteinuria (values too high), or bacteriuria/leukocyturia (values too low or too high) could be found. In alkaline urine (pH > 7.0), SG values obtained by reagent strip have to be corrected by +5.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mode of access: Internet.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Reprinted from the Transactions of the Royal society of Edinburgh, vol. XLIX, part I, 1912.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

"Supersedes U.S. Department of Agriculture Tech. Bull. No. 168 of same title."

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of the research program was to evaluate the heat strain, hydration status, and heat illness symptoms experienced by surface mine workers. An initial investigation involved 91 surface miners completing a heat stress questionnaire; assessing the work environment, hydration practices, and heat illness symptom experience. The key findings included 1) more than 80 % of workers experienced at least one symptom of heat illness over a 12 month period; and 2) the risk of moderate symptoms of heat illness increased with the severity of dehydration. These findings highlight a health and safety concern for surface miners, as experiencing symptoms of heat illness is an indication that the physiological systems of the body may be struggling to meet the demands of thermoregulation. To illuminate these findings a field investigation to monitor the heat strain and hydration status of surface miners was proposed. Two preliminary studies were conducted to ensure accurate and reliable data collection techniques. Firstly, a study was undertaken to determine a calibration procedure to ensure the accuracy of core body temperature measurement via an ingestible sensor. A water bath was heated to several temperatures between 23 . 51 ¢ªC, allowing for comparison of the temperature recorded by the sensors and a traceable thermometer. A positive systematic bias was observed and indicated a need for calibration. It was concluded that a linear regression should be developed for each sensor prior to ingestion, allowing for a correction to be applied to the raw data. Secondly, hydration status was to be assessed through urine specific gravity measurement. It was foreseeable that practical limitations on mine sites would delay the time between urine collection and analysis. A study was undertaken to assess the reliability of urine analysis over time. Measurement of urine specific gravity was found to be reliable up to 24 hours post urine collection and was suitable to be used in the field study. Twenty-nine surface miners (14 drillers [winter] and 15 blast crew [summer]) were monitored during a normal work shift. Core body temperature was recorded continuously. Average mean core body temperature was 37.5 and 37.4 ¢ªC for blast crew and drillers, with average maximum body temperatures of 38.0 and 37.9 ¢ªC respectively. The highest body temperature recorded was 38.4 ¢ªC. Urine samples were collected at each void for specific gravity measurement. The average mean urine specific gravity was 1.024 and 1.021 for blast crew and drillers respectively. The Heat Illness Symptoms Index was used to evaluate the experience of heat illness symptoms on shift. Over 70 % of drillers and over 80 % of blast crew reported at least one symptom. It was concluded that 1) heat strain remained within the recommended limits for acclimatised workers; and 2) the majority of workers were dehydrated before commencing their shift, and tend to remain dehydrated for the duration. Dehydration was identified as the primary issue for surface miners working in the heat. Therefore continued study focused on investigating a novel approach to monitoring hydration status. The final aim of this research program was to investigate the influence dehydration has on intraocular pressure (IOP); and subsequently, whether IOP could provide a novel indicator of hydration status. Seven males completed 90 minutes of walking in both a cool and hot climate with fluid restriction. Hydration variables and intraocular pressure were measured at baseline and at 30 minute intervals. Participants became dehydrated during the trial in the heat but maintained hydration status in the cool. Intraocular pressure progressively declined in the trial in the heat but remained relatively stable when hydration was maintained. A significant relationship was observed between intraocular pressure and both body mass loss and plasma osmolality. This evidence suggests that intraocular pressure is influenced by changes in hydration status. Further research is required to determine if intraocular pressure could be utilised as an indirect indicator of hydration status.